AcuRite Iris™ (5-in-1), Notos® (3-in-1), Tower Sensors, and Humidity Monitors:
Models: 06004, 06014, 06008, 00592TXR/06002M, 00606TX/06009RMA1, 00609TXRA1, and non-Pro Accuracy Humidity Monitors.
- Temperature: +/- 2 degrees Fahrenheit (+/- 1.11 degrees Celsius).
- Humidity:
- +/- 5% from 0% to 10% Relative Humidity.
- +/- 4% from 10% to 20% Relative Humidity.
- +/- 3% from 20% to 80% Relative Humidity.
- +/- 4% from 80% to 90% Relative Humidity.
- +/- 5% from 90% to 100% Relative Humidity.
- Rain: +/- 0.05" per inch of rainfall.
- Wind Speed:
-
+/-2 mph below 10 mph.
-
+/- 3 mph from 10 to 30 mph.
-
+/- 4 mph from 30 to 50 mph.
-
+/- 5 mph from 50 to 99 mph.
-
- Barometric Pressure: +/- .15 inhg.
AcuRite Atlas® Sensor:
Model #06059
- Temperature: +/- 1 degree Fahrenheit (+/- .56 degrees Celsius)
- Humidity: +/- 2% Relative Humidity.
- Rain: +/- 5%.
- Wind Speed: +/- 1 mph < 10 mph, +/- 10% > 10 mph.
- Wind Direction: +/- 3 degrees.
- UV Accuracy: +/- 1.
- Barometric Pressure: +/- .15 inhg.
Pro Accuracy Units:
Models: 01080M, 01083M, and 01139M.
- Temperature: +/- 0.5 degrees Fahrenheit.
- Humidity: +/- 2% Relative Humidity.
Portable Anemometer Model #00256M
- Temperature: +/- 2 degrees Fahrenheit (+/- 1.11 degrees Celsius).
- Humidity: +/- 1% Relative Humidity.
- Wind Speed:
-
+/-2 mph below 10 mph.
-
+/- 3 mph from 10 to 30 mph.
-
+/- 4 mph from 30 to 50 mph.
-
+/- 5 mph from 50 to 60 mph.
-
Digital/Analog Clocks:
- Time: +/- 1 second per day.
AcuRite AIR™ Indoor Air Quality Monitor:
- +/- 10µg/m3 from 0µg/m3 to 100µg/m3
- +/- 10% from 100µg/m3 to 500µg/m3